Resumen
Critical linear buckling load calculation is one of the possible ways to check structural stability. Structural analysis programs usually model beams and columns with just one element, but this is not enough to obtain an accurate value of the critical buckling load when the buckling mode is associated with an effective length that is less than twice the element length. This paper presents a method for the accurate calculation of the buckling load of frames modeled with only one finite element per structural element. For this purpose, a local correction is applied to some elements a few times until convergence is achieved. The validity of the presented method is confirmed by several examples ranging from simple canonical cases to large structures.