Show simple item record

dc.contributor.authorAzkorra Larrinaga, Zaloa
dc.contributor.authorMartín Escudero, Koldobika ORCID
dc.contributor.authorRomero Antón, Naiara
dc.date.accessioned2024-06-18T17:22:24Z
dc.date.available2024-06-18T17:22:24Z
dc.date.issued2024
dc.identifier.citationEkaia 45 : 259-278 (2024)
dc.identifier.issn0214-9001
dc.identifier.urihttp://hdl.handle.net/10810/68511
dc.description.abstractSistema berdeak sendotzen ari dira hirietako eskari termikoa murrizteko eta, aldi berean, hiriko bizitzaren kalitatea hobetzeko. Sistema berdeei lotutako onurak hainbat dira: biodibertsitatea handitzea, ekaitz-uren kontrola, energia aurreztea, tenperatura erregulatzea eta zarata arintzea. Landaredun sistema bertikalek errendimendu energetikoari egiten dioten ekarpenari buruzko ezagutza lortzeko, landaredun fatxada bati proba metodo-logikoak egin zaizkio Paslink zelda batean. Helburua landare-fatxada modular baten berokuntza- eta hozte-eskaria ezaugarritzea da. Emaitza nagusia isolamenduaren hobekuntza izan da. Erreferentziako fatxada 0.75 W/(m2°C) baliotik abiatzen zen, eta 1.22 W/(m2°C)-ko transmisio termikoko balioetara igaro zen landare-fatxadari esker; horrek esan nahi du isolamendu-ahalmena %30 handitu zela. Fatxada berdeek energia aurrezteko potentzialtasun handia dutela ondoriozta daiteke.; Modular living walls are being strengthened to reduce thermal demand in cities while improving the quality of life in the city. The benefits associated with green systems are increased biodiversity, storm water control, energy saving, temperature regulation and noise mitigation. In order to gain knowledge of the contribution of vertical plant systems to energy performance, methodological tests of the modular living wall have been conducted in a Paslink test cell. The objective is to characterize the heating and cooling demand of a modular living wall. The main result is the improvement of isolation. The reference façade started from a value of 0.75 W/(m2°C) and went to a thermal transmission value of 1.22 W/(m2°C) thanks to the green façade, which means that insulation capacity increased by 30%. It can be concluded that modular living walls have great energy saving potential.
dc.language.isoeus
dc.publisherServicio Editorial de la Universidad del País Vasco/Euskal Herriko Unibertsitatearen Argitalpen Zerbitzua
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/4.0/
dc.titleEraikin pasiboen karakterizazio termikoa: landare-fatxada modular baten kasu-azterketa
dc.typeinfo:eu-repo/semantics/article
dc.rights.holder© 2024 UPV/EHU Attribution-NonCommercial-ShareAlike 4.0 International
dc.identifier.doi10.1387/ekaia.24600


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

© 2024 UPV/EHU Attribution-NonCommercial-ShareAlike 4.0 International
Except where otherwise noted, this item's license is described as © 2024 UPV/EHU Attribution-NonCommercial-ShareAlike 4.0 International