Show simple item record

dc.contributor.advisorGranados Domínguez, María Cristina
dc.contributor.authorGarate Iturzaeta, Iker
dc.contributor.otherF. ACTIVIDAD FISICA Y DEPORTE
dc.contributor.otherJARDUERA FISIKOAREN ETA KIROLAREN ZIENTZIEN F.
dc.date.accessioned2023-09-05T17:51:37Z
dc.date.available2023-09-05T17:51:37Z
dc.date.issued2023-09-05
dc.identifier.urihttp://hdl.handle.net/10810/62370
dc.description26 p. -- Bibliogr.: p. 15-19
dc.description.abstractBackground Physical fitness, and especially cardiorespiratory fitness, are very important indicators of health in the general population, and even more so in people with disabilities. In order to measure cardiorespiratory fitness correctly, it is necessary to use valid and reliable tests, and to do so, these psychometric properties must be measured beforehand. Objective The aim of this systematic review is to know which cardiopulmonary tests have been evaluated for psychometric properties in people with disabilities and which of these tests are reliable and valid for this population. Methods PubMed, Scopus, SPORTDiscus and Web of Science databases were searched on 30 November 2020. After screening 563 studies, 35 articles met the inclusion criteria: a) participants had any physical, intellectual or sensory disability; b) the test under study measured cardiorespiratory fitness; c) the article provided information on reliability or validity of the test; and d) studies must be original articles. The quality of the studies was assessed according to the COSMIN checklist and this was taken into account when establishing the evidence for each test. Results Data from a total of 1126 people (370 females and 756 males) have been included in this review, analysing 29 different tests. 23 studies had people with intellectual disabilities as a population, 10 had people with physical disabilities and there were only 2 articles with people with visual disabilities. Conclusion In people with intellectual disabilities (including those with Down's Syndrome) the six-minute walking test and the shuttle run tests (16 and 20 metre versions) appear to be the tests with the best reliability and validity and the Gold Standard is considered to be an incremental treadmill test. In people with physical disabilities no clear conclusions could be drawn, as the literature seems to be scattered. The incremental wheelchair test has been proposed as a possible Gold Standard versus the arm crank ergometer test for wheelchair-dependent people or wheelchair sports players. In visually impaired people there are very few studies and more research is needed.es_ES
dc.language.isoenges_ES
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectdisabilityes_ES
dc.subjectfield test
dc.subjectlaboratory test
dc.subjectaerobic endurance
dc.subjectadapted sport
dc.titleValidity and reliability of cardiopulmonary tests for people with disabilities: a sistematic reviewes_ES
dc.title.alternativeUrritasunak dituzten pertsonentzako test kardiopulmonarren baliozkotasuna eta fidagarritasuna: errebisio sistematikoaes_ES
dc.typeinfo:eu-repo/semantics/masterThesis
dc.date.updated2021-05-27T14:30:43Z
dc.language.rfc3066es
dc.rights.holder© 2021, el autor
dc.contributor.degreeMaster Universitario en Ciencias de la Actividad Física y del Deporte
dc.contributor.degreeJarduera Fisikoaren eta Kirolaren Zientziak Unibertsitate Masterra
dc.identifier.gaurregister112715-831962-08es_ES
dc.identifier.gaurassign118403-831962es_ES


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record