dc.description.abstract | Interest in robotic devices for rehabilitation has increased in the last years, due to the increasing number of patients that require rehabilitation therapies, and the need to optimize existing resources. The UHP rehabilitation robot is a multifunctional device that allows to execute robotized therapies for the upper-limb using a simple pantograph based reconfigurable structure and the implementation of advanced position/force control approaches. However, in applications such as rehabilitation, where the robotic device interacts directly with the user, complying with the demands of the users is as important
as complying with the functional requirements. Otherwise, the patient will reject the robotic device. Therefore, in this work the pre-clinical validation of the UHP upper-limb rehabilitation robotic platform is presented. 25 subjects of different physical characteristics have participated in the evaluation of the device, evaluating not only the correct behaviour of the device, but also its safety and adaptativity. Results show the correct behaviour of the platform, and a good acceptance rate of the device. | es_ES |
dc.description.sponsorship | This work was supported in part by the Basque Country Governments (GV/EJ) under grant PRE-2014-1-152, UPV/EHU’s PPG17/56 project, Basque Country Governments IT914-16 project, Spanish Ministry of Economy and Competitiveness’ MINECO & FEDER inside DPI2017-82694-R project, Euskampus, FIK and Spanish Ministry of Science and Innovation PDI-020100-2009-21 project. | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | IEEE | es_ES |
dc.relation | info:eu-repo/grantAgreement/MINECO/DPI2017-82694-R | es_ES |
dc.rights | info:eu-repo/semantics/openAccess | es_ES |
dc.title | Pre-clinical validation of the UHP multifunctional upper-limb rehabilitation robot based platform | es_ES |
dc.type | info:eu-repo/semantics/conferenceObject | es_ES |
dc.rights.holder | © 2018, IEEE | es_ES |
dc.relation.publisherversion | https://ieeexplore.ieee.org/document/8593527 | es_ES |
dc.identifier.doi | 10.1109/IROS.2018.8593527 | |
dc.departamentoes | Ingeniería de sistemas y automática | es_ES |
dc.departamentoeu | Sistemen ingeniaritza eta automatika | es_ES |