Now showing items 1-6 of 6

    • Thumbnail

      Hardware and software architecture for overhead line rating monitoring 

      Albizu Flórez, Igor ORCID; Fernández Herrero, Elvira ORCID; Mazón Sainz-Maza, Angel Javier ORCID; Bengoechea Aresti, Janire; Torres Iglesias, Esther (IEEE, 2011-06)
      Real time monitoring in both electrical transmission and distribution lines is an interesting option for knowing the electrical load level of these lines. The information about the load level allows alleviating the overloaded ...
    • Thumbnail

      Methods for Increasing the Rating of Overhead Lines 

      Albizu Flórez, Igor ORCID; Mazón Sainz-Maza, Angel Javier ORCID; Zamora Belver, Inmaculada (IEEE, 2011-06)
      At the present time, there is great pressure to increase the power flow in existing right of ways using existing infrastructure as far as possible. In this paper, the diverse options for increasing the rating of overhead ...
    • Thumbnail

      Monitoring the Tension and the Temperature in an Overhead Line 

      Bedialauneta Landaribar, Miren Terese ORCID; Albizu Flórez, Igor ORCID; Fernández Herrero, Elvira ORCID; Mazón Sainz-Maza, Angel Javier ORCID; De Arriba, Susana (IEEE, 2012-03)
      The paper describes a monitoring system for the evaluation of the low sag behavior of the overhead conductors. The monitoring system measures the conductor tension and temperature. This system includes a methodology for ...
    • Thumbnail

      On-Line Stator Winding Fault Diagnosis in Induction Generators for Renewable Generation 

      Albizu Flórez, Igor ORCID; Tapia Otaegui, María Aranzazu; Sáenz Ruiz, Jose Ramón; Mazón Sainz-Maza, Angel Javier ORCID; Zamora Belver, Inmaculada (IEEE, 2004-05)
      Renewable generation systems are increasing its presence in electrical power systems. For this reason, it is more important than ever to count with reliable and secure generation systems. In this way, the use of on-line ...
    • Thumbnail

      Overhead conductor monitoring system for the evaluation of the low sag behavior 

      Albizu Flórez, Igor ORCID; Fernández Herrero, Elvira ORCID; Mazón Sainz-Maza, Angel Javier ORCID; Bedialauneta Landaribar, Miren Terese ORCID; Sagastabeitia Buruaga, Koldobika Joseba (IEEE, 2011-06)
      The paper describes a monitoring system for the evaluation of the low sag behavior of the overhead conductors in operating lines. The monitoring system measures the conductor tension and temperature and it also measures ...
    • Thumbnail

      System for ampacity monitoring and low sag overhead conductor evaluation 

      Fernández Herrero, Elvira ORCID; Albizu Flórez, Igor ORCID; Bedialauneta Landaribar, Miren Terese ORCID; De Arriba, Susana; Mazón Sainz-Maza, Angel Javier ORCID (IEEE, 2012)
      Among the different alternatives to achieve the uprating and better use of existing overhead power lines are the use of high temperature low sag conductors and the use of real time monitoring systems for knowing the ampacity ...