Relationship Between Energy Demand, Indoor Thermal Behaviour and Temperature-Related Health Risk Concerning Passive Energy Refurbishment Interventions
(Sciendo, 2020-09)
The main objective of this article is to demonstrate that passive energy refurbishment interventions influence comfort conditions of households for both cold and hot annual periods, while they help to avoid or promote ...
Environmental and Economic Prioritization of Building Energy Refurbishment Strategies with Life-Cycle Approach
(MDPI, 2020-05-11)
An increasing number of studies apply life-cycle assessment methodology to assess the impact of a new building or to prioritize between different building refurbishment strategies. Among the different hypotheses to consider ...
An Integrated Approach to Transportation and Land-Use Planning for the Analysis of Former Railway Nodes in Sustainable Transport Development: The Case of the Vasco-Navarro Railway
(MDPI, 2020-12-31)
The disappearance of kilometers of railways that once structured their surrounding territory has become an alarming issue in the last decades. These days, several disused railway infrastructures have been converted into ...
Airtightness Analysis of the Built Heritage–Field Measurements of Nineteenth Century Buildings through Blower Door Tests
(MDPI, 2020-12-20)
Airtightness is a major issue in architectural design and it has a significant impact on the energy performance of buildings. Moreover, the energy behaviour of built heritage is due, to its singular characteristics, still ...
Data on records of indoor temperature and relative humidity in a University building
(Elsevier, 2017-08)
Good indoor comfort and air quality are essential for correct educational development. Most reports in this field focus on primary and secondary school buildings, with numerous projects conducted in the Mediterranean Zone. ...
Fachadas ventiladas activas para reducir la demanda de calefacción en los edificios de oficinas. El caso de España
(CSIC, 2012-12-20)
En este artículo se analiza la eficiencia energética de una Fachada Ventilada Activa –FVA– aplicada a edificios de oficinas
en España para reducir la demanda de calefacción.
El sistema de fachada consiste en una hoja ...
The Ekihouse: An energy self-sufficient house based on passive design strategies
(Elsevier, 2014-11)
EKIHOUSE is an industrialized solar house prototype designed and developed by the University of the Basque Country for the SOLAR DECATHLON EUROPE 2012 competition that took place in Madrid (Spain). The building design ...