dc.identifier.citationEnergies 12(12) : (2019) // Article ID 2404es_ES
dc.identifier.issn1996-1073
dc.identifier.urihttp://hdl.handle.net/10810/41344
dc.description.abstractIntegration of wind energy into the grid faces a great challenge regarding power quality. The International Electrotechnical Commission (IEC) 61400-21 standard defines the electrical characteristics that need to be assessed in a Wind Turbine (WT), as well as the procedure to measure the disturbances produced by the WT. One of the parameters to be assessed are voltage fluctuations or flicker. To estimate the flicker emission of a Wind Power Plant (WPP), the standard establishes that a quadratic exponent should be used in the summation of the flicker emission of each WT. This exponent was selected based on studies carried out in WPPs with type I and II WTs. Advances in wind turbine technology have reduced their flicker emission, mainly thanks to the implementation of power electronics for the partial or total management of the power injected into the grid. This work is based on measurements from a WPP with 16 type III WTs. The flicker emission of a single WT and of the WPP were calculated. Low flicker emission values at the Point of Common Coupling (PCC) of the WPP were obtained. The flicker estimation at the PCC, based on the measurement from a single WT, was analyzed using different exponents. The results show that a cubic summation performs better than the quadratic one in the estimation of the flicker emission of a WPP with type III WTs.es_ES
dc.description.sponsorshipThis research was funded by Basque Government (Basque Country, Spain) through the project IT1087-16 and by the Spanish MINECO through project DPI2014-53317-R (co-financed with European FEDER funds).es_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.relationinfo:eu-repo/grantAgreement/MINECO/DPI2014-53317-Res_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.subjectpower qualityes_ES
dc.subjectwind power plantes_ES
dc.subjectvoltage fluctuationses_ES
dc.subjectemissiones_ES
dc.titleExperimental Study of the Summation of Flicker Caused by Wind Turbineses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.holderThis is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. (CC BY 4.0)es_ES
dc.rights.holderAtribución 3.0 España*
dc.relation.publisherversionhttps://www.mdpi.com/1996-1073/12/12/2404es_ES
dc.identifier.doi10.3390/en12122404
dc.departamentoesIngeniería de comunicacioneses_ES
dc.departamentoesIngeniería de sistemas y automáticaes_ES
dc.departamentoeuKomunikazioen ingeniaritzaes_ES
dc.departamentoeuSistemen ingeniaritza eta automatikaes_ES


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. (CC BY 4.0)
Except where otherwise noted, this item's license is described as This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. (CC BY 4.0)