Show simple item record

dc.contributor.authorVelarde-Sotres, Álvaro
dc.contributor.authorBores-Cerezal, Antonio
dc.contributor.authorMecías-Calvo, Marcos
dc.contributor.authorCarvajal-Altamiranda, Stefanía
dc.contributor.authorCalleja González, Julio María ORCID
dc.date.accessioned2021-05-28T10:53:51Z
dc.date.available2021-05-28T10:53:51Z
dc.date.issued2021-05-11
dc.identifier.citationInternational Journal of Environmental Research and Public Health 18(10) : (2021) // Article ID 5057es_ES
dc.identifier.issn1660-4601
dc.identifier.urihttp://hdl.handle.net/10810/51661
dc.description.abstractThe articular evaluation of range of motion (ROM) is currently used to observe imbalance or limitations as possible risk factors or predispositions to suffer future injures. The main aim of this study is to verify the concurrent validity, reliability and reproducibility of the OctoBalance Test (OB) as a valid and reliable tool to measure articular ROM of the upper limb compared to the modified-Upper Quarter Y-Balance Test (mUQYBT). The twenty-five participants were male athletes. All of them were assessed with OB and mUQYBT in medial, superolateral, and inferolateral directions in both right and left arms with a three-minute break during these attempts. The process was repeated a second time with a week gap between measurements. Pearson correlation and linear logarithmic regression were used to examine the relationship between scores obtained with OB and mUQYBT. In order to verify the reliability, the intraclass correlation coefficient (ICC) was used (3.1). Concordance and reproducibility were assessed using Bland–Altman’s graph. A perfect correlation and an almost linear logarithmic regression (R2 = 0.97) were observed between both measurement systems, with values of 73.531 ± 21.226 cm in mUQYBT and 69.541 ± 16.330 cm in OB. The differences were minimal between week one and week two. The assessment with Bland’s graph showed the concordance and reproducibility of scores, showing the dispersion and the upper and lower limits. OB is shown as valid in comparison to the other test as a reliable and reproducible tool for the assessment of the articular ROM in the upper limb, and it could be used for the evaluation of injuries.es_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/
dc.subjectOctoBalance testes_ES
dc.subjectinjury preventiones_ES
dc.subjectneuromuscular assessmentes_ES
dc.subjectupper limbes_ES
dc.subjectfunctional testses_ES
dc.titleValidity, Reliability and Reproducibility of OctoBalance Test as Tool to Measure the Upper Limb Compared to Modified-Upper Quarter Y-Balance Testes_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.date.updated2021-05-24T15:07:05Z
dc.rights.holder2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).es_ES
dc.relation.publisherversionhttps://www.mdpi.com/1660-4601/18/10/5057/htmes_ES
dc.identifier.doi10.3390/ijerph18105057
dc.departamentoesEducación física y deportiva
dc.departamentoeuGorputz eta Kirol Hezkuntza


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Except where otherwise noted, this item's license is described as 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).