Assessing the Utility and Patient Satisfaction of Virtual Retina Clinics During COVID-19 Pandemic
dc.contributor.author | Juaristi, Leire | |
dc.contributor.author | Irigoyen, Cristina | |
dc.contributor.author | Chapartegui, Jaione | |
dc.contributor.author | Guibelalde González, Ane | |
dc.contributor.author | Mar Medina, Javier | |
dc.date.accessioned | 2022-09-12T18:14:42Z | |
dc.date.available | 2022-09-12T18:14:42Z | |
dc.date.issued | 2022 | |
dc.identifier.citation | Clinical Ophthalmology 16 : 311-321 (2022) | es_ES |
dc.identifier.issn | 1177-5483 | |
dc.identifier.uri | http://hdl.handle.net/10810/57701 | |
dc.description.abstract | [EN] Purpose: To explore whether the virtual retina clinic (VRC) has been a useful and safe platform for monitoring retinal diseases during the COVID-19 pandemic and assessing patient satisfaction. Methods: A prospective observational study was conducted for patients with stable retinal diseases in Donostia University Hospital's Ophthalmology Service during the pandemic. All patients were assessed in the VRC with optical coherence tomography of the macula and widefield retinography, plus visual field tests in hydroxychloroquine retinopathy screenings. The VRC's effectiveness was evaluated with repeat blind assessments and patient satisfaction with an adapted SERVQUAL scale. Results: The most common diseases were diabetic retinopathy (30.3%) and age-related macular degeneration (21.8%). Most patients (74%) were eligible to continue in the VRC, 19.3% were referred to face-to-face (F2F) appointments and 6.6% were discharged. Patients underwent repeat blind assessments in F2F appointments to monitor VRC performance in 23.7% of the cases. The sensitivity to detect disease progression was 100%. The specificity was 80.1%. The VRC took half the time. The patient overall satisfaction rating was 9.8/10. Conclusion: The VRC, as an additional platform, supports F2F appointments. Almost three-quarters of patients could continue being safely seen in the VRC. The virtual approach decreases SARS-CoV-2 exposure. Patient satisfaction is very good. | es_ES |
dc.description.sponsorship | Bottom-Up grant from the Basque Government Health Department | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | Dove Medical Press | es_ES |
dc.rights | info:eu-repo/semantics/openAccess | es_ES |
dc.rights.uri | http://creativecommons.org/licenses/by-nc/3.0/es/ | * |
dc.subject | clarus ultra-widefield camera | es_ES |
dc.subject | SARS-CoV-2 exposure | es_ES |
dc.subject | virtual retina clinic | es_ES |
dc.subject | teleretina | es_ES |
dc.subject | widefield fundus retinography | es_ES |
dc.title | Assessing the Utility and Patient Satisfaction of Virtual Retina Clinics During COVID-19 Pandemic | es_ES |
dc.type | info:eu-repo/semantics/article | es_ES |
dc.rights.holder | © 2022 Juaristi et al. This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms. php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php | es_ES |
dc.rights.holder | Atribución-NoComercial 3.0 España | * |
dc.relation.publisherversion | https://www.dovepress.com/assessing-the-utility-and-patient-satisfaction-of-virtual-retina-clini-peer-reviewed-fulltext-article-OPTH | es_ES |
dc.identifier.doi | 10.2147/OPTH.S349939 | |
dc.departamentoes | Dermatología, oftalmología y otorrinolaringología | es_ES |
dc.departamentoeu | Dermatologia, oftalmologia eta otorrinolaringologia | es_ES |
Files in this item
This item appears in the following Collection(s)
Except where otherwise noted, this item's license is described as © 2022 Juaristi et al. This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.
php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the
work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For
permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php