Show simple item record

dc.contributor.authorGiménez Calvo, Galadriel
dc.contributor.authorBartol Puyal, Francisco de Asís
dc.contributor.authorAltemir, Irene
dc.contributor.authorMéndez Martínez, Silvia
dc.contributor.authorAlmenara, Cristina
dc.contributor.authorSoriano Pina, Diana
dc.contributor.authorMurueta-Goyena Larrañaga, Ane
dc.contributor.authorLarrosa, Manuel
dc.date.accessioned2023-06-29T15:40:55Z
dc.date.available2023-06-29T15:40:55Z
dc.date.issued2023-03
dc.identifier.citationInternational Ophthalmology 43(3) : 945-955 (2023)es_ES
dc.identifier.issn0165-5701
dc.identifier.issn1573-2630
dc.identifier.urihttp://hdl.handle.net/10810/61797
dc.description.abstractBackground To assess the influence of biometric measurements on the defocus curve after the implantation of enlarged depth-of-focus (EDoF) intraocular lens (IOL). Methods Patients who underwent cataract surgery with bilateral implantation of Tecnis Symfony IOL were enrolled. Preoperatively, axial length (AL), corneal keratometry (K), pupil size and corneal aberrations were measured. 1 month after surgery, distance, intermediate, and near visual acuities (VA) were recorded. At 3 months, monocular and binocular corrected contrast sensitivities under photopic and mesopic lighting conditions were measured with CSV-1000E test. At 6-months, the defocus curve between −5.00 to + 3.00 diopters (D) was assessed in steps of 0.50 D, and NEI-RQL-42 questionnaire was administered. Results One hundred thirty one eyes of 66 patients were included. Binocular logMAR VA better than 0.1 for intermediate vision was obtained in 90% of patients, whereas only 17.7% obtained that result in near vision. The rate of satisfaction was high (96%) and most of them (85.5%) had no or little difficulties in near vision. The mean amplitude of the defocus curve was 2.35D ± 0.73D, and smaller AL, smaller pupils, younger age, and male sex were associated with wider range of clear vision. Conclusions Tecnis Symfony IOL enables functional vision at all distances, but demographic variables and preoperative biometric measurements like AL and pupil size influence the postoperative amplitude of the defocus curve. These parameters could be used to predict the performance of EDoF IOLs.es_ES
dc.description.sponsorshipOpen Access funding provided thanks to the CRUE-CSIC agreement with Springer Nature.es_ES
dc.language.isoenges_ES
dc.publisherSpringeres_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by/3.0/es/*
dc.subjectmultifocal IOLses_ES
dc.subjectEDoF IOLses_ES
dc.subjectdiffractivees_ES
dc.subjectcataractes_ES
dc.subjectquality of visiones_ES
dc.titleInfluence of ocular biometric factors on the defocus curve in an enlarged depth-of-focus intraocular lenses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.holder© The Author(s) 2022. This article is licensed under a Creative Com- mons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Crea- tive Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http:// creat iveco mmons. org/ licen ses/ by/4. 0/.es_ES
dc.rights.holderAtribución 3.0 España*
dc.relation.publisherversionhttps://link.springer.com/article/10.1007/s10792-022-02496-yes_ES
dc.identifier.doi10.1007/s10792-022-02496-y
dc.departamentoesNeurocienciases_ES
dc.departamentoeuNeurozientziakes_ES


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

© The Author(s) 2022. This article is licensed under a Creative Com-
mons Attribution 4.0 International License, which permits
use, sharing, adaptation, distribution and reproduction in any
medium or format, as long as you give appropriate credit to the
original author(s) and the source, provide a link to the Crea-
tive Commons licence, and indicate if changes were made. The
images or other third party material in this article are included
in the article’s Creative Commons licence, unless indicated
otherwise in a credit line to the material. If material is not
included in the article’s Creative Commons licence and your
intended use is not permitted by statutory regulation or exceeds
the permitted use, you will need to obtain permission directly
from the copyright holder. To view a copy of this licence, visit
http:// creat iveco mmons. org/ licen ses/ by/4. 0/.
Except where otherwise noted, this item's license is described as © The Author(s) 2022. This article is licensed under a Creative Com- mons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Crea- tive Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http:// creat iveco mmons. org/ licen ses/ by/4. 0/.