Show simple item record

dc.contributor.authorLorenzo Ruiz, Iñigo ORCID
dc.date.accessioned2023-07-17T11:27:42Z
dc.date.available2023-07-17T11:27:42Z
dc.date.issued2023-04-28
dc.identifier.citationPacing and Clinical Electrophysiology 46(7) : 623–628 (2023)es_ES
dc.identifier.issn0147-8389
dc.identifier.issn1540-8159
dc.identifier.urihttp://hdl.handle.net/10810/61994
dc.description.abstractBackground: While in high-income countries (HICs) the implantation of cardiac implantable electronic devices (CIEDs) is common, in certain low- and middle-income countries (LMICs) access to devices is limited and insufficient to meet the demand. Between 17% and 30% of CIEDs explanted post-mortem in HICs appears to have enough battery life to be reused but devices are not routinely programmed to no pacing output and continue to consume battery after the patient’s death. Therefore, we conducted a prospective analysis of CIEDs collected from funeral homes, controlling variables such as the date of explantation and limiting the time until the date of interrogation to 6 months. The objective was to perform an accurate analysis of the reusability of post-mortem explanted CIEDs to assess the possibility of implementing a local effort of CIED reuse in LMICs.___ Methods: A descriptive study of post-mortem explanted CIEDs in funeral homes was conducted. Participating centers stored all devices explanted between December 2020 to December 2021 for collection and interrogation. Results: The participating centers attended 6472 deaths (28.05% of total deaths registered in the region). Two hundred fourteen CIEDs were collected (90.2% pacemakers and 9.8% defibrillators). Of the 214 collected devices, 100 CIEDs (46.7%) had >4 years or >75% battery remaining, preserved external integrity, and no evidence of malfunction and therefore were considered reusable. ___ Conclusions: Based on stablished criteria 46.7% of recovered devices were considered reusable. Therefore, recovery from funeral homes of HICs comprises a potential source of reusable devices for LMICs.es_ES
dc.description.sponsorshipOpen Access Funding provided by the University of the Basque Country, UPV/EHU.es_ES
dc.language.isoenges_ES
dc.publisherWileyes_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/es/*
dc.subjectCRTes_ES
dc.subjectICDes_ES
dc.subjectpacemakeres_ES
dc.subjectpost-mortemes_ES
dc.subjectreusees_ES
dc.titleLongevity and potential reusability of cardiac implantable electronic devices explanted in funeral homeses_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.rights.holderAtribución-NoComercial-CompartirIgual 3.0 Españaes_ES
dc.relation.publisherversionhttps://onlinelibrary.wiley.com/doi/epdf/10.1111/pace.14703es_ES
dc.relation.publisherversionhttps://doi.org/10.1111/pace.14703es_ES
dc.identifier.doi10.1111/pace.14703
dc.departamentoesEnfermeríaes_ES