Wearable Slot Antenna at 2.45 GHz for Off-Body Radiation: Analysis of Efficiency,Frequency Shift, and Body Absorption
Ver/
Fecha
2017-09-12Autor
Fernández Andrés, Marta
Espinosa, Hugo
Thiel, David
Arrinda Sanzberro, Amaia
Metadatos
Mostrar el registro completo del ítem
Bioelectromagnetics 39(1) : 25-34 (2018)
Resumen
The interaction of body-worn antennas with the human body causes a significant decrease in antenna efficiency and a shift in resonant frequency. A resonant slot in a small conductive box placed on the body has been shown to reduce these effects. The specific absorption rate is less than international health standards for most wearable antennas due to small transmitter power.This paper reports the linear relationship between power absorbed by biological tissues at different locations on the body and radiation efficiency based on numerical modeling(r ¼ 0.99). While the 10 dB bandwidth of the antenna remained constant and equal to 12.5%,the maximum frequency shift occurred when the antenna was close to the elbow (6.61%) andon the thigh (5.86%). The smallest change was found on the torso (4.21%). Participants with body-mass index (BMI) between 17 and 29 kg/m 2 took part in experimental measurements,where the maximum frequency shift was 2.51%. Measurements showed better agreement with simulations on the upper arm. These experimental results demonstrate that the BMI for each individual had little effect on the performance of the antenna.