Quantitative determination of fentanyl in newborn pig plasma and cerebrospinal fluid samples by HPLC-MS/MS
View/ Open
Date
2015-03-09Author
Blanco, María Encarnación
Encinas Pérez, Esther
Rico Parrilla, Estitxu
Vozmediano, Valvanera
Suárez González, María Elena
Metadata
Show full item record
Drug Testing and Analysis 7(9) : 804-811 (2015)
Abstract
In this study, a selective and sensitive high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method requiring low sample volume (≤100 μL) was developed and validated for the quantitative determination of the opioid drug fentanyl in plasma and cerebrospinal fluid (CSF). A protein precipitation extraction with acetonitrile was used for plasma samples whereas CSF samples were injected directly on the HPLC column. Fentanyl and 13C6-fentanyl (Internal Standard) were analyzed in an electrospray ionization source in positive mode, with multiple reaction monitoring (MRM) of the transitions m/z 337.0/188.0 and m/z 337.0/105.0 for quantification and confirmation of fentanyl, and m/z 343.0/188.0 for 13C6-fentanyl. The respective lowest limits of quantification for plasma and CSF were 0.2 and 0.25 ng/mL. Intra- and inter-assay precision and accuracy did not exceed 15%, in accordance with bioanalytical validation guidelines. The described analytical method was proven to be robust and was successfully applied to the determination of fentanyl in plasma and CSF samples from a pharmacokinetic and pharmacodynamic study in newborn piglets receiving intravenous fentanyl (5 µg/kg bolus immediately followed by a 90-min infusion of 3 µg/kg/h).